Feb 29, 2024 Leave a message

Tell you what is the difference between traditional air conditioning and chiller?

Is it better to use traditional air conditioning or industrial environmental air conditioning to cool the factory? Customers who do not understand that these two products are similar, traditional air conditioning and industrial environmental protection air conditioning, water-cooled air conditioning is actually two completely different things. Not only the appearance, structure, price, energy consumption, cooling effect, even the working principle is completely different, today for you to explain in depth what is the difference between these two air conditioners?

 

One: Cooling capacity Cooling efficiency is different

After the national third party authoritative certification body identified (national compressor refrigeration equipment quality inspection center) a single 1.1kw chiller cooling capacity of 24.8kw equivalent to a 10P air conditioning cooling capacity, energy efficiency ratio of 21.75kw/kw ultra-high efficiency.

Two: Traditional air conditioning and industrial environmental protection air conditioning, water-cooled air conditioning working principle is different:

 

DSC7959

 

How traditional air conditioners work: Air conditioners use freon as a refrigerant. The characteristic of freon is that when it changes from a gas to a liquid state, it releases a large amount of heat. And when you go from a liquid to a gas, you absorb a lot of heat. (i.e. first endothermic gasification and then liquefaction heat release) air conditioning is designed according to this principle; The compressor compresses the gaseous refrigerant into a high-temperature and high-pressure gaseous refrigerant, and then sends it to the condenser (outdoor unit) to dissipate heat and become a liquid refrigerant at room temperature and high pressure, so the outdoor unit blows out hot air; Then to the capillary, into the evaporator (indoor unit), because the refrigerant from the capillary to the evaporator space suddenly increases, the pressure is reduced, the liquid refrigerant will vaporize, into a gaseous low temperature refrigerant, thereby absorbing a lot of heat, the evaporator will become cold, the indoor fan will blow the air from the evaporator, so the indoor machine is blown out of the cold air;

 

The working principle of water-cooled air conditioning: according to the natural physical phenomenon of "water evaporation absorbs heat, evaporation area affects evaporation efficiency", indoor air supply through the fan network, outdoor fresh air flows through the soaked wet curtain after the air and water fully contact at the same time absorb the sensible heat in the air, so as to achieve ventilation, cooling, ventilation, dust removal. The purpose of increasing indoor oxygen content.

 

Three: Air conditioning and water-cooled air conditioning coverage area:

Coverage area of air conditioning: 23 units below 10㎡ (small horse: power is about 750W)

10㎡-14㎡ 26 machine (big one: power is about 1200W)

14㎡-18㎡ 32 machine (small one and a half: the power is about 1100W)

16㎡-20㎡ 35 machine (plus one and a half: the power is about 1102.5W)

20㎡-32㎡ 50 machine (two pieces: the power is about 1500W)

30㎡-45㎡ 61 machine (two and a half: the power is about 1850W)

45㎡-55㎡ 75 machine (three pieces: the power is about 2300W)

Note: The above data comes from the space covered by the air conditioner without shelter and heat source.

For example: the factory area of 1000 square meters, workers work 10 hours a day, taking the traditional air conditioning machine as an example: 0.75KW(power)×100 units (quantity)×10h(time) = 750KW

 

Environmental protection air conditioning coverage area:

18000m3/h air volume covering 100-150㎡ (power is about 1100W)

22000m3/h air volume covering 150-200㎡ (power about 1500W)

30000m3/h air volume covering 200-250㎡ (power is about 2200W)

For example: the factory area of 1000 square meters, workers work 10 hours a day, with 18000m3/h air volume as an example: 1.1KW(power)×10 units (quantity)×10h(time) = 110KW

No more than a surprise, from the two examples also obtained, environmental protection air conditioning and air conditioning energy consumption comparison is self-evident.

 

Note: The above data comes from the space covered by the environmental air conditioner with no shelter and no heat source.

In this case, there is no professional data, because the air conditioner has a compressor, so the cooling effect is better; The environmental protection air conditioning is the use of water evaporation cooling, the corresponding cooling effect is certainly not as good as the traditional air conditioning cooling effect, in summary, it should be said that each has advantages and disadvantages, the traditional air conditioning cooling effect is good, but the energy consumption is very high; Although the cooling effect of environmental protection air conditioning is not as good as that of air conditioning, the energy consumption is very low, and it can meet the daily ventilation and cooling needs of workers.

Send Inquiry

whatsapp

Phone

E-mail

Inquiry